Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 11.251
Filtrar
1.
Clin Orthop Surg ; 16(2): 201-209, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38562642

RESUMO

Background: Proximal-distal mismatch has emerged as a prominent concern in Dorr type A femoral morphology, prompting the exploration of short stems as promising alternatives to conventional stems. This study aimed to evaluate clinical and radiographic outcomes of total hip arthroplasty (THA) using short femoral stems in Dorr type A proximal femoral morphology with a minimum follow-up of 5 years. Methods: Patients with short femoral stems in Dorr type A between 2011 and 2017 were included. Patients with the Short Modular Femoral (SMF) stem and Metha stem were recruited and patients with a shortened tapered stem (Tri-Lock BPS) were matched by propensity score matching based on age, sex, body mass index, calcar to canal ratio, and diagnosis. Patient-reported outcomes and the presence of thigh pain were assessed at 5 years postoperatively. Revision rate, complication rate, and radiographic outcomes were also assessed and compared. Results: Twenty-two cases (81%) in the SMF stem and 43 cases (65%) in the Metha stem had more than 5 years of follow-up data available. The SMF stem showed a higher failure rate than the other 2 groups, with 18% requiring revision surgery in the SMF stem compared to 4.6% in the Metha stem, and 2.3% in the Tri-Lock BPS. The SMF stem showed considerable complications such as stem position change and lateral cortical hypertrophy with inferior clinical outcomes than the other 2 stem groups. When the Metha stem and the Tri-Lock BPS groups were compared, more intraoperative fractures were observed in the Metha stem, whereas stress shielding and anterior thigh pain were significantly more prevalent in the Tri-Lock BPS. Conclusions: The SMF stem might be less reliable than previously reported, showing a high failure rate and increased radiologic complications. Thus, its use for THA in Dorr Type A femurs needs caution. On the other hand, the Metha stem showed comparable outcomes to the shortened tapered Tri-Lock BPS.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Sobrevivência , Desenho de Prótese , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Reoperação , Dor/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Seguimentos
2.
PLoS One ; 19(4): e0299996, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38603691

RESUMO

Maintaining post-operative mechanical stability is crucial for successfully healing intertrochanteric fractures treated with the Proximal Femoral Nail Antirotation (PFNA) system. This stability is primarily dependent on the bone mineral density (BMD) and strain on the fracture. Current PFNA failure analyses often overlook the uncertainties related to BMD and body weight (BW). Therefore, this study aimed to develop a probabilistic model using finite element modeling and engineering reliability analysis to assess the post-operative performance of PFNA under various physiological loading conditions. The model predictions were validated through a series of experimental test. The results revealed a negative nonlinear relationship between the BMD and compressive strain. Conversely, the BW was positively and linearly correlated with the compressive strain. Importantly, the compressive strain was more sensitive to BW than to BMD when the BMD exceeded 0.6 g/cm3. Potential trabecular bone compression failure is also indicated if BMD is equal to or below 0.15 g/cm3 and BW increases to approximately 2.5 times the normal or higher. This study emphasizes that variations in the BMD significantly affect the probability of failure of a PFNA system. Thus, careful planning of post-operative physical therapy is essential. For patients aged > 50 years restrictions on high-intensity activities are advised, while limiting strenuous movements is recommended for those aged > 65 years.


Assuntos
Fixação Intramedular de Fraturas , Fraturas do Quadril , Humanos , Fixação Intramedular de Fraturas/métodos , Reprodutibilidade dos Testes , Pinos Ortopédicos , Fraturas do Quadril/cirurgia , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Resultado do Tratamento , Estudos Retrospectivos
3.
Med Eng Phys ; 126: 104153, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38621850

RESUMO

The Iterative Close Point (ICP) algorithm is used for bone registrations based on ultrasound measurements. However, the ICP has been shown to suffer from local minima. The Complex optimization, as a more robust routine compared to the commonly used gradient-based algorithms, could be an alternative for solving the ICP problem. In this study, we investigated the effect of the initial estimate and the number of registration points on bone registrations achieved using the ICP and a Complex optimization routine and we compared it against using Quadratic Sequential Programming (SQP). Ultrasound measurements were performed with an A-mode probe on a bovine humerus and an ovine femur embedded into ballistic gel. Simultaneously, the bones and the probe were tracked in 3D space using retroreflective markers. Kinematic, ultrasound and geometrical data obtained from scans of the specimens and the probe served as input to a bone registrations routine. Registrations were performed using two ICP solvers for different initial estimates and number of registration points. On average, 68 % of the Complex optimization registrations had less than 1 mm translation error and less than 1° rotational error for perturbations of the initial estimate from the reference measurements compared to the 35 % of the SQP ones. Similar medians of registration errors were observed between the two methods for variations of the number of the employed registration points. Although the Complex optimization provided accurate bone registrations for all cases, the objective function could not always determine the registrations with the smallest registration error. Future research should explore methodologies to overcome this challenge.


Assuntos
Algoritmos , Osso e Ossos , Animais , Bovinos , Ovinos , Ultrassonografia , Osso e Ossos/diagnóstico por imagem , Fêmur/diagnóstico por imagem , Extremidade Inferior , Imageamento Tridimensional/métodos
4.
BMC Musculoskelet Disord ; 25(1): 312, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38649874

RESUMO

BACKGROUND: Hip offset, version, and length are interdependent femoral variables which determine stability and leg length. Balancing these competing variables remains a core challenge in hip arthroplasty. The potential benefits of modular femoral stems have been overshadowed by higher rates of failure. The objective of this study was to assess the survivorship of a unique dual-modular femoral stem at an average 15-year follow-up period. METHODS: The records of all patients with osteoarthritis who underwent primary total hip arthroplasty with this device between 2004-2009 were reviewed. There were no exclusions for BMI or other factors. We examined the data with Kaplan-Meier survival analysis. The primary endpoint for survival was mechanical failure of the modular neck-body junction. RESULTS: The survivorship of this device in 172 subjects was 100% with none experiencing mechanical failure of the modular junction at an average of 15 years. 60 patients died of causes unrelated to their THA and 9 patients were lost to follow-up. There were three early (≤ 12 months) dislocations (1.7%), and seven total dislocations (4.1%). 16 patients underwent reoperations during the follow-up period, none for any complication of the modular junction. Radiographic results showed well-fixed femoral stems in all cases. There were no leg length discrepancies of greater than 10 mm, and 85% were within 5 mm. CONCLUSION: There were no mechanical failures of the modular junction in any of the subjects over the average 15-year period, demonstrating that this dual-modular design is not associated with increased failure rates. We achieved a 1.7% early dislocation rate and a 4.1% total dislocation rate without any clinically significant leg length discrepancies.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Desenho de Prótese , Falha de Prótese , Humanos , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Adulto , Seguimentos , Osteoartrite do Quadril/cirurgia , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Estimativa de Kaplan-Meier , Reoperação/estatística & dados numéricos , Fêmur/cirurgia , Fêmur/diagnóstico por imagem , Fatores de Tempo
5.
Sci Rep ; 14(1): 7029, 2024 03 25.
Artigo em Inglês | MEDLINE | ID: mdl-38528237

RESUMO

Proximal femoral fractures are a serious life-threatening injury with high morbidity and mortality. Magnetic resonance (MR) imaging has potential to non-invasively assess proximal femoral bone strength in vivo through usage of finite element (FE) modelling (a technique referred to as MR-FE). To precisely assess bone strength, knowledge of measurement error associated with different MR-FE outcomes is needed. The objective of this study was to characterize the short-term in vivo precision errors of MR-FE outcomes (e.g., stress, strain, failure loads) of the proximal femur for fall and stance loading configurations using 13 participants (5 males and 8 females; median age: 27 years, range: 21-68), each scanned 3 times. MR-FE models were generated, and mean von Mises stress and strain as well as principal stress and strain were calculated for 3 regions of interest. Similarly, we calculated the failure loads to cause 5% of contiguous elements to fail according to the von Mises yield, Brittle Coulomb-Mohr, normal principal, and Hoffman stress and strain criteria. Precision (root-mean squared coefficient of variation) of the MR-FE outcomes ranged from 3.3% to 11.8% for stress and strain-based mechanical outcomes, and 5.8% to 9.0% for failure loads. These results provide evidence that MR-FE outcomes are a promising non-invasive technique for monitoring femoral strength in vivo.


Assuntos
Fêmur , Extremidade Inferior , Masculino , Feminino , Humanos , Adulto , Análise de Elementos Finitos , Fêmur/diagnóstico por imagem , Acidentes por Quedas , Imageamento por Ressonância Magnética
6.
Rom J Morphol Embryol ; 65(1): 89-97, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38527988

RESUMO

The present research study aimed to assess magnetic resonance imaging (MRI) changes and histological findings in the therapeutic effects of microfractures in the treatment of complex animal knee lesions resulting from osteochondral and meniscal defects resulting from non-total meniscectomies. The anterior cruciate ligament lesions are also proven to facilitate the development of osteoarthritis in the knee and worsen the prognosis. Surgery was performed on the right knee joint of 22 male rabbits in order to partially remove the anterior horn of the internal meniscus and to induce an osteochondral defect at the level of the internal femoral condyle. The induced lesion complex was aimed to simulate a clinical situation that occurs frequently in orthopedic practice when young adults undergo partial meniscectomy and at the time of surgery, an osteochondral defect is diagnosed. Rabbits were separated into two study groups: the control (C1) group and the microfractures (MF2) group. After the induced cartilage defect and partial meniscectomy, both groups were followed-up for six months using detailed MRI. Also, anatomical specimens were histologically analyzed to show modifications and signs of healing process, along with complications, in the study group. The results showed that the microfracture group had better results concerning articular surface defect healing in comparison to the control group. Our results suggest that microfractures do improve results concerning surface contact healing and serial MRI studies can be useful in observing the remodeling process in dynamics.


Assuntos
Cartilagem Articular , Fraturas de Estresse , Animais , Masculino , Coelhos , Fraturas de Estresse/patologia , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Ligamento Cruzado Anterior , Imageamento por Ressonância Magnética/métodos , Fêmur/diagnóstico por imagem , Cartilagem Articular/diagnóstico por imagem , Cartilagem Articular/patologia , Cartilagem Articular/cirurgia
7.
Acta Orthop Traumatol Turc ; 58(1): 39-44, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38525509

RESUMO

OBJECTIVE: The aim of this study was to evaluate the posterior condylar angle (PCA) and condylar twist angle (CTA) of the distal femur in the Turkish population and its concordance with the current standard prosthesis guides used in total knee arthroplasty (TKA). METHODS: Two hundred and forty knees of 120 Turkish subjects (60 male and 60 female) were included in this study. PCA, CTA, femoral mediolateral lengths (fML), medial femoral anteroposterior lengths (fMAP), lateral femoral anteroposterior lengths (fLAP), distances between the trochlear groove and fMAP (DBTG-fMAP), distances between the trochlear groove and fLAP (DBTG-fLAP), medial posterior condylar cartilage thickness (MPCCT) and lateral posterior condylar cartilage thicknesses (LPCCT) were measured on magnetic resonance imaging (MRI). RESULTS: The median CTA was 7° (range: 0°-13.0°) and the median PCA was 4° (range 0°-11.0°) (P < .0001). The median fML was 79.5 mm (range: 65.7-98.9). The median length of the fMAP was 58.2 mm (range: 46.8-69.0) and the median length of fLAP was 58.2 mm (range: 48.4-73.0). The DBTG-fMAP was 15.2 mm (range: 5.2-23.2), and DBTG-fLAP length was 21.9mm (range: 16.4-29.4). The median MPCCT and LPCCT were 2.4 mm (range: 1.6-3.6) and 2.3 mm (range: 1.2-2.8), respectively. The intraclass correlation coefficient for quantifying interobserver and intraobserver reliability showed excellent agreement regarding the PCA and CTA. CONCLUSION: This study has shown us that PCA and CTA may be higher in the Turkish population. Although it is not known whether these results have any clinical utility, it may be useful for surgeons to keep this in mind to prevent femoral component malposition. LEVEL OF EVIDENCE: Level IV, Diagnostic Study.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Humanos , Masculino , Feminino , Artroplastia do Joelho/métodos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Reprodutibilidade dos Testes , Fluormetolona , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Osteoartrite do Joelho/cirurgia
8.
Sci Rep ; 14(1): 7403, 2024 03 28.
Artigo em Inglês | MEDLINE | ID: mdl-38548805

RESUMO

Quantitative computed tomography (QCT)-based in silico models have demonstrated improved accuracy in predicting hip fractures with respect to the current gold standard, the areal bone mineral density. These models require that the femur bone is segmented as a first step. This task can be challenging, and in fact, it is often almost fully manual, which is time-consuming, operator-dependent, and hard to reproduce. This work proposes a semi-automated procedure for femur bone segmentation from CT images. The proposed procedure is based on the bone and joint enhancement filter and graph-cut algorithms. The semi-automated procedure performances were assessed on 10 subjects through comparison with the standard manual segmentation. Metrics based on the femur geometries and the risk of fracture assessed in silico resulting from the two segmentation procedures were considered. The average Hausdorff distance (0.03 ± 0.01 mm) and the difference union ratio (0.06 ± 0.02) metrics computed between the manual and semi-automated segmentations were significantly higher than those computed within the manual segmentations (0.01 ± 0.01 mm and 0.03 ± 0.02). Besides, a blind qualitative evaluation revealed that the semi-automated procedure was significantly superior (p < 0.001) to the manual one in terms of fidelity to the CT. As for the hip fracture risk assessed in silico starting from both segmentations, no significant difference emerged between the two (R2 = 0.99). The proposed semi-automated segmentation procedure overcomes the manual one, shortening the segmentation time and providing a better segmentation. The method could be employed within CT-based in silico methodologies and to segment large volumes of images to train and test fully automated and supervised segmentation methods.


Assuntos
Fêmur , Fraturas do Quadril , Humanos , Fêmur/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Extremidade Inferior , Fraturas do Quadril/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos
9.
PLoS One ; 19(3): e0283823, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38551890

RESUMO

BACKGROUND: Severe and complex angular limb deformities in dogs require accurate morphological assessment using diagnostic imaging to achieve successful orthopedic surgery. Computed tomography (CT) is commonly used to overcome projection errors in two-dimensional angular measurements of dog hindlimb alignment. Three-dimensional volume rendering (VR) techniques permit virtual positioning and variable projection, but the final CT-image that defines the projection plane for angular measurements remains two-dimensional. OBJECTIVE: We wanted to develop a true three-dimensional open-source technique to measure the alignments of the hind limbs of dogs in CT scanners. METHODS: We developed an open-source 3D Slicer plug-in, to perform angular measurements using vector calculations in three-dimensional space. In 113 CT-scans of canine pelvic limbs, femoral torsion, femoral varus, femorotibial rotation, tibial torsion, tibial varus and tibiotalar rotation angles were calculated and compared to an already validated technique using VoXim®. RESULTS: Reference points were identified and measurements were possible in the 113 acquisitions. The greatest difference between the two techniques was 1.4° at only one tibial torsion angle. Mean values for all Bland-Altman plots did not show significant differences and were less than 0.07° for all comparisons. DISCUSSION: Based on these results we considered angular measurements of canine hind limb alignment in CT scans using the 3D Slicer extension program sufficiently accurate for clinical orthopedic and surgical purposes in veterinary medicine. CONCLUSION: With our open-source 3D Slicer extension software, we provide a free accessible tool for veterinary orthopedic surgeons and thus we hope to improve angular measurements in CT-scans of canine hind limb deformities through true three-dimensionality.


Assuntos
Extremidade Inferior , Tíbia , Cães , Animais , Extremidade Inferior/anatomia & histologia , Membro Posterior/diagnóstico por imagem , Tíbia/diagnóstico por imagem , Tíbia/anatomia & histologia , Tomografia Computadorizada por Raios X/métodos , Fêmur/diagnóstico por imagem , Fêmur/anatomia & histologia , Software , Imageamento Tridimensional/métodos
11.
Appl Radiat Isot ; 208: 111296, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38508065

RESUMO

This study aimed to investigate the effect of diabetes on radiation attenuation parameters of the femur and tibia of rats using Monte Carlo Simulations. First, control and diabetic rats were identified and tibias and femurs were removed. Then, the elemental ratios of the bones obtained were calculated using EDS (Energy Dissipative X-ray Spectroscopy). Therefore, radiation permeability properties of control and diabetic bones were simulated by using the content ratios in the bones in MCNP6 (Monte Carlo N-Particle) and PHITS (Particle and Heavy Ion Transport code System) 3.22 and Stopping and Range of Ions in Matter (SRIM) simulation codes. Attenuation coefficient results were compared with the NIST database via XCOM. Although differences in absorption coefficients are observed at low energies, these differences disappear as the energy increases.


Assuntos
Diabetes Mellitus Experimental , Tíbia , Ratos , Animais , Tíbia/diagnóstico por imagem , Projetos Piloto , Simulação por Computador , Fêmur/diagnóstico por imagem , Método de Monte Carlo
12.
Oper Orthop Traumatol ; 36(2): 96-104, 2024 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-38536427

RESUMO

OBJECTIVE: A rotational osteotomy requires a complete cut of the bone in order to correct maltorsion. An additional correction of the frontal axis can be achieved via an oblique cut of the bone. The osteotomy with bone to bone contact is fixed with an angle stable plate. INDICATIONS: Symptoms such as anterior knee pain, inwardly pointing knee syndrome, lateral patellar subluxation or dislocation, lateral patellar hypercompression syndrome are a common indication for derivational osteotomy if clinically increased femoral internal rotation and radiologically increased femoral antetorsion is detected. CONTRAINDICATIONS: Increased hip external rotation versus internal rotation, increased femoral torsion but no increased internal hip rotation, malcompliance, inability for partial weight bearing, risk of delayed union (nicotine abuse and obesity) as well as patellofemoral arthritis and systematic glucocorticoids, immunosuppressants are (relative) contra-indications. SURGICAL TECHNIQUE: A lateral or optionally medial approach to the distal femur and exposure of the bone with Eva hooks for the osteotomy is done. The use of patient-specific cutting blocks accurately specify the planned extent of derotation and level of incision. A defined oblique cutting plane of the single-cut osteotomy and derotation will additionally correct/change frontal axis. An additional biplanar osteotomy with an anterior wedge increases intraoperative stability and generates a larger bone contact area for consolidation. POSTOPERATIVE MANAGEMENT: With the use of an extra medullary fixation device partial weight bearing with 15-20 kg with crutches up to 6 weeks is required, but no restriction on knee movement is given. RESULTS: The literature shows significantly improved patient satisfaction regarding patellofemoral stability and knee function. With the use of patient-specific cutting guides, high accuracy of the osteotomy and 3­dimensional correction can be achieved, while delayed union rate is up to 10%.


Assuntos
Fêmur , Luxações Articulares , Humanos , Resultado do Tratamento , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Articulação do Joelho/cirurgia , Patela , Osteotomia/métodos
13.
J Bone Miner Res ; 39(3): 298-314, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38477790

RESUMO

Osteocytes sense and respond to mechanical force by controlling the activity of other bone cells. However, the mechanisms by which osteocytes sense mechanical input and transmit biological signals remain unclear. Voltage-sensitive calcium channels (VSCCs) regulate calcium (Ca2+) influx in response to external stimuli. Inhibition or deletion of VSCCs impairs osteogenesis and skeletal responses to mechanical loading. VSCC activity is influenced by its auxiliary subunits, which bind the channel's α1 pore-forming subunit to alter intracellular Ca2+ concentrations. The α2δ1 auxiliary subunit associates with the pore-forming subunit via a glycosylphosphatidylinositol anchor and regulates the channel's calcium-gating kinetics. Knockdown of α2δ1 in osteocytes impairs responses to membrane stretch, and global deletion of α2δ1 in mice results in osteopenia and impaired skeletal responses to loading in vivo. Therefore, we hypothesized that the α2δ1 subunit functions as a mechanotransducer, and its deletion in osteocytes would impair skeletal development and load-induced bone formation. Mice (C57BL/6) with LoxP sequences flanking Cacna2d1, the gene encoding α2δ1, were crossed with mice expressing Cre under the control of the Dmp1 promoter (10 kb). Deletion of α2δ1 in osteocytes and late-stage osteoblasts decreased femoral bone quantity (P < .05) by DXA, reduced relative osteoid surface (P < .05), and altered osteoblast and osteocyte regulatory gene expression (P < .01). Cacna2d1f/f, Cre + male mice displayed decreased femoral strength and lower 10-wk cancellous bone in vivo micro-computed tomography measurements at the proximal tibia (P < .01) compared to controls, whereas Cacna2d1f/f, Cre + female mice showed impaired 20-wk cancellous and cortical bone ex vivo micro-computed tomography measurements (P < .05) vs controls. Deletion of α2δ1 in osteocytes and late-stage osteoblasts suppressed load-induced calcium signaling in vivo and decreased anabolic responses to mechanical loading in male mice, demonstrating decreased mechanosensitivity. Collectively, the α2δ1 auxiliary subunit is essential for the regulation of osteoid-formation, femur strength, and load-induced bone formation in male mice.


The ability of bone to sense and respond to forces generated during daily physical activities is essential to skeletal health. Although several bone cell types contribute to the maintenance of bone health, osteocytes are thought to be the primary mechanosensitive cells; however, the mechanisms through which these cells perceive mechanical stimuli remains unclear. Previous work has shown that voltage sensitive calcium channels are necessary for bone to sense mechanical force; yet the means by which those channels translate the physical signal into a biochemical signal is unclear. Data within this manuscript demonstrate that the extracellular α2δ1 subunit of voltage sensitive calcium channels is necessary for load-induced bone formation as well as to enable calcium influx within osteocytes. As this subunit enables physical interactions of the channel pore with the extracellular matrix, our data demonstrate the need for the α2δ1 subunit for mechanically induced bone adaptation, thus serving as a physical conduit through which mechanical signals from the bone matrix are transduced into biochemical signals by enabling calcium influx into osteocytes.


Assuntos
Osteócitos , Osteogênese , Camundongos , Masculino , Feminino , Animais , Osteócitos/metabolismo , Osteogênese/genética , Cálcio/metabolismo , Microtomografia por Raio-X , Camundongos Endogâmicos C57BL , Osteoblastos/metabolismo , Fêmur/diagnóstico por imagem , Fêmur/metabolismo , Canais de Cálcio/genética , Canais de Cálcio/metabolismo
14.
J Biomech ; 166: 112046, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38467079

RESUMO

Full-length radiographs contain information from which many anatomical parameters of the pelvis, femur, and tibia may be derived, but only a few anatomical parameters are used for musculoskeletal modeling. This study aimed to develop a fully automatic algorithm to extract anatomical parameters from full-length radiograph to generate a musculoskeletal model that is more accurate than linear scaled one. A U-Net convolutional neural network was trained to segment the pelvis, femur, and tibia from the full-length radiograph. Eight anatomic parameters (six for length and width, two for angles) were automatically extracted from the bone segmentation masks and used to generate the musculoskeletal model. Sørensen-Dice coefficient was used to quantify the consistency of automatic bone segmentation masks with manually segmented labels. Maximum distance error, root mean square (RMS) distance error and Jaccard index (JI) were used to evaluate the geometric accuracy of the automatically generated pelvis, femur and tibia models versus CT bone models. Mean Sørensen-Dice coefficients for the pelvis, femur and tibia 2D segmentation masks were 0.9898, 0.9822 and 0.9786, respectively. The algorithm-driven bone models were closer to the 3D CT bone models than the scaled generic models in geometry, with significantly lower maximum distance error (28.3 % average decrease from 24.35 mm) and RMS distance error (28.9 % average decrease from 9.55 mm) and higher JI (17.2 % average increase from 0.46) (P < 0.001). The algorithm-driven musculoskeletal modeling (107.15 ± 10.24 s) was faster than the manual process (870.07 ± 44.79 s) for the same full-length radiograph. This algorithm provides a fully automatic way to generate a musculoskeletal model from full-length radiograph that achieves an approximately 30 % reduction in distance errors, which could enable personalized musculoskeletal simulation based on full-length radiograph for large scale OA populations.


Assuntos
Redes Neurais de Computação , Tíbia , Radiografia , Tíbia/diagnóstico por imagem , Fêmur/diagnóstico por imagem , Pelve , Processamento de Imagem Assistida por Computador
15.
Reumatol Clin (Engl Ed) ; 20(3): 162-165, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38443229

RESUMO

Gluteal pain is a frequent cause of medical attention in the daily clinical practice. It can be caused by multiple pathologies, being ischiofemoral impingement syndrome among those included in its differential diagnosis. Encompassed within the deep gluteal syndromes, this entity occurs as a consequence of the entrapment of the neuromuscular structures between the lesser femoral trochanter and the ischial tuberosity, causing pain in the root of the lower limb, with irradiation towards the thigh or the gluteal region and poor tolerance to deambulation and sedestation. The magnetic resonance imaging of the hip is fundamental for its diagnosis, and its management consists on medical treatment at onset. Despite not being a frequent diagnosis in the clinical practice in Rheumatology, keeping it in mind helps improving its prognosis by establishing an early and adequate treatment.


Assuntos
Ísquio , Dor Musculoesquelética , Humanos , Ísquio/diagnóstico por imagem , Ísquio/patologia , Imageamento por Ressonância Magnética/métodos , Fêmur/diagnóstico por imagem , Fêmur/patologia , Extremidade Inferior
16.
Knee Surg Sports Traumatol Arthrosc ; 32(5): 1199-1206, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38511851

RESUMO

PURPOSE: The purpose of this study was to find out whether the torsions of the femur and tibia are dependent on the coronal plane alignment of the knee (CPAK) type. METHODS: Five hundred patients (1000 legs) were included, who received a whole leg standing three-dimensional (3D) radiograph using EOS imaging (EOS Imaging, Paris, France). SterEOS software was used for digital reconstruction. Femoral and tibial torsions were determined by analysing 3D reconstructions of each leg. Femoral torsion was defined as the angle between the femoral neck axis (FNA) and the posterior condylar axis (PCA). Tibial torsion was defined as the angle between the axis tangent to the posterior part of the tibia plateau and the transmalleolar axis. Arithmetic hip-knee-ankle angle (aHKA) and joint-line obliquity (JLO) were also determined, allowing each leg to be assigned one of nine possible phenotypes according to CPAK. RESULTS: The mean femoral torsion in CPAK type 1 was significantly higher (+ 2.6° ± 0.8°) than in CPAK type 4 (p = 0.02). All other CPAK types did not differ in the degree of femoral torsions. No differences could be demonstrated for the tibial torsion. CONCLUSION: There is a correlation between the coronal alignment of the lower limb and femoral torsion. This may provide the basis for extending the CPAK classification beyond the coronal plane. LEVEL OF EVIDENCE: Level III.


Assuntos
Fêmur , Imageamento Tridimensional , Articulação do Joelho , Tíbia , Humanos , Fêmur/diagnóstico por imagem , Fêmur/anatomia & histologia , Feminino , Masculino , Adulto , Articulação do Joelho/diagnóstico por imagem , Pessoa de Meia-Idade , Tíbia/diagnóstico por imagem , Idoso , Anormalidade Torcional/diagnóstico por imagem , Adulto Jovem , Radiografia , Adolescente
17.
Knee Surg Sports Traumatol Arthrosc ; 32(5): 1332-1343, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38520187

RESUMO

PURPOSE: This study aimed to elucidate the characteristics of varus knee deformities in the Japanese population, prevalence of various around knee osteotomy procedures and influence of femoral and tibial bowing. METHODS: Varus knee deformity was defined as a weight-bearing line ratio of <50%. A total of 1010 varus knees were selected from 1814 varus knees with weight-bearing full-length radiographs, obtained at two facilities, based on exclusion criteria. Various parameters were measured, and around knee osteotomy simulations based on the deformity centre were conducted using digital planning tools. Bowing of the femoral and tibial shafts was measured, with bowing defined as follows: ≤ -0.6° indicating lateral bowing and ≥ 0.6° indicating medial bowing. Statistical analysis was performed to investigate age-related correlations and their impact on surgical techniques. RESULTS: The study revealed that the proximal tibia was the centre of deformity in Japanese varus knees (42.8%), and high tibial osteotomy was frequently indicated (81.6%). Age demonstrated a mild correlation with femoral shaft bowing (r = -0.29), leading to an increase in the mechanical lateral distal femoral angle and to a decrease in the hip-knee-ankle angle and weight-bearing line ratio (r = -0.29, 0.221, 0.219). The tibial shaft bowing was unaffected by age (r = -0.022). CONCLUSION: A significant proportion of Japanese individuals with varus knees exhibit a deformity centre located in the proximal tibia, making them suitable candidates for high tibial osteotomy. No age-related alterations were discerned in tibial morphology, indicating that the occurrence of constitutional varus knees is attributable to tibial deformities in the Japanese patient cohort. LEVEL OF EVIDENCE: Level IV.


Assuntos
Articulação do Joelho , Osteotomia , Tíbia , Humanos , Osteotomia/métodos , Tíbia/cirurgia , Tíbia/anormalidades , Tíbia/diagnóstico por imagem , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Japão , Articulação do Joelho/cirurgia , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/anormalidades , Idoso , Radiografia , Fêmur/cirurgia , Fêmur/anormalidades , Fêmur/diagnóstico por imagem , Adulto Jovem , Suporte de Carga , Adolescente , População do Leste Asiático
18.
J Orthop Surg Res ; 19(1): 189, 2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38500214

RESUMO

PURPOSE: The aim of this study is to find a new method for femoral side preservation positioning in anterior cruciate ligament (ACL) reconstruction and test the accuracy and precision of this method. METHOD: Fifty patients with isolated ACL rupture (42 males and 8 females) who underwent single-bundle ACL reconstruction in our hospital between July 2022 and July 2023 were included. The lowest point of the cartilage margin of the lateral wall of the intercontinental fossa and the tibial plateau plumb line at 120° of knee flexion were used as the anatomical landmarks for positioning of the femoral tunnel for ACL reconstruction surgery. Femoral side remnant preservation was performed in all cases. Three-dimensional CT was performed 3 days postoperatively to collect the data, which were analyzed using Mimics 21.0 software. We measured the posterior cortical distance of the femoral condyle at 90° of knee flexion and the vertical distance from the center of the bone tunnel to the cortical extension line behind the femur. All femoral tunnel positions were marked on a 4 × 4 grid and visualized using the quadrant method. RESULTS: Using the new positioning method in 50 knees, the average distance of x was 25.26 ± 2.76% of t and the average distance of y was 23.69 ± 6.19% of h. This is close to the results of previous studies, where x was 24.2 ± 4.0% of t and the average distance of y was 21.6 ± 5.2% of h. Most femoral tunnel positions were located in the same area. The D values were distributed as follows: 60% in the range of 0 to 2 mm, 24% in the range of 2 to 4 mm, and 16% more than 4 mm. The E values were distributed as follows: 80% in the range of 0 to 4 mm and 20% more than 4 mm. CONCLUSION: In arthroscopic ACL reconstruction, the knee was flexed at 120° and the lowest point of the cartilage edge of the lateral wall of the intercondylar fossa and the tibial plateau plumb line were used as anatomical landmarks for the positioning of the femoral bone tunnel, which resulted in more accurate femoral bone tunnel positioning, better reproducibility, and better preservation of the femoral stump compared to traditional positioning methods.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Masculino , Feminino , Humanos , Reprodutibilidade dos Testes , Articulação do Joelho/cirurgia , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Tíbia/cirurgia , Lesões do Ligamento Cruzado Anterior/diagnóstico por imagem , Lesões do Ligamento Cruzado Anterior/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos
19.
Sci Rep ; 14(1): 5536, 2024 03 06.
Artigo em Inglês | MEDLINE | ID: mdl-38448630

RESUMO

We aimed to establish a new method of obtaining femur anteroposterior radiographs from live rats. We used five adult male Sprague-Dawley rats and created a femoral fracture model with an 8 mm segmental fragment. After the surgery, we obtained two femoral anteroposterior radiographs, a novel overhead method, and a traditional craniocaudal view. We obtained the overhead method three times, craniocaudal view once, and anteroposterior radiograph of the isolated femoral bone after euthanasia. We compared the overhead method and craniocaudal view with an isolated femoral anteroposterior view. We used a two-sample t-test and intraclass correlation coefficient (ICC) to estimate the intra-observer reliability. The overhead method had significantly smaller differences than the craniocaudal view for nail length (1.53 ± 1.26 vs. 11.4 ± 3.45, p < 0.001, ICC 0.96) and neck shaft angle (5.82 ± 3.8 vs. 37.8 ± 5.7, p < 0.001, ICC 0.96). No significant differences existed for intertrochanteric length/femoral head diameter (0.23 ± 0.13 vs. 0.23 ± 0.13, p = 0.96, ICC 0.98) or lateral condyle/medial condyle width (0.15 ± 0.16 vs. 0.13 ± 0.08, p = 0.82, ICC 0.99). A fragment displacement was within 0.11 mm (2.4%). The overhead method was closer to the isolated femoral anteroposterior view and had higher reliability.


Assuntos
Fraturas do Fêmur , Masculino , Animais , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes , Fraturas do Fêmur/diagnóstico por imagem , Fêmur/diagnóstico por imagem , Espinhas Dendríticas
20.
JBJS Case Connect ; 14(1)2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38452160

RESUMO

CASE: A 16-year-old boy presented with a recurrent distal femur aneurysmal bone cyst accompanied by a combined sagittal knee deformity (20° of femoral antecurvatum and 26.8° of tibial recurvatum) and limb shortening. After preoperative planning, the treatment involved new intralesional curettage, phenolization, and bone allograft filling. Additional procedures included distal extension femoral osteotomy with plate fixation, and proximal tibial osteotomy with, gradually corrected through a hexapod frame. At 2-year follow-up, lower limbs exhibited normoalignment and equal length. CONCLUSION: Complex knee deformities may occur with tumoral lesions around the knee but can be effectively addressed through double osteotomy and application of a hexapod frame.


Assuntos
Cistos Ósseos Aneurismáticos , Deformidades Articulares Adquiridas , Masculino , Humanos , Adolescente , Cistos Ósseos Aneurismáticos/complicações , Cistos Ósseos Aneurismáticos/diagnóstico por imagem , Cistos Ósseos Aneurismáticos/cirurgia , Deformidades Articulares Adquiridas/complicações , Deformidades Articulares Adquiridas/cirurgia , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Fêmur/anormalidades , Tíbia/diagnóstico por imagem , Tíbia/cirurgia , Articulação do Joelho/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...